Banner
Produkte
Heim /

YOKOGAWA

/Yokogawa ANT502-50/BU1A S1 Optical ESB Bus Repeater Slave Module
Yokogawa ANT502-50/BU1A S1
Yokogawa ANT502-50/BU1A S1
Yokogawa ANT502-50/BU1A S1

Yokogawa ANT502-50/BU1A S1 Optical ESB Bus Repeater Slave Module

OPTICAL ESB BUS REPEATER SLAVE MODULE

ANT502-50/BU1A S1

Yokogawa ANT502-50/BU1A S1 is a Yokogawa optical ESB bus repeater slave module for a 5 km optical link. It receives the optical ESB connection from the matching master-side hardware and connects the node-side ESB bus.

PRODUCT TYPEOptical ESB Slave
BASE MODELANT502
MAX DISTANCE5 km / hop
OPTICAL PORTLC
BRANDYokogawa
PRODUCT TYPEOptical ESB Bus Repeater Slave Module
CONDITION / WARRANTYOriginal New · One-Year Warranty
VERIFICATIONPair the -50 variant with ANT401-□0 or -□3 master hardware under the documented optical-link configuration. /BU1A provides a connector unit with an ESB bus connector.
REQUEST A QUOTE
MODEL SEARCHFind a specific part numberOpen the best-matched Moore Automation product page directly.
PRODUCT INFORMATION● OFFICIAL YOKOGAWA REFERENCE
OPTICAL ESB BUS TRANSPORT

ANT502-50/BU1A S1

OPTICAL ESB BUS REPEATER SLAVE MODULE

5 km per hop · LC optical connector · Slave side

PRODUCT ROLE
ANT502-50/BU1A S1 is a Yokogawa optical ESB bus repeater slave module for a 5 km optical link. It receives the optical ESB connection from the matching master-side hardware and connects the node-side ESB bus.
INSTALLATION CHECK
Pair the -50 variant with ANT401-□0 or -□3 master hardware under the documented optical-link configuration. /BU1A provides a connector unit with an ESB bus connector.
👩‍💼
WANT THE BEST PRICE?
Frida
Sales Leader 🏆
EMAILsales5@mooreplc.comWHATSAPP+86 153 5940 8275
OFFICIAL YOKOGAWA REFERENCE

Technical Specifications

VERIFY COMPLETE MODULE REFERENCE
ANT502-50/BU1A S1

Engineering data at a glance

Click “+” to expand more specifications.

MAX HOP5 km
OPTICAL PORTLC
FIBER CORES2 cores
CURRENT0.5 A
Installation requirement
Use two-core single-mode optical fiber with LC connectors. Pair the -50 variant with ANT401-□0 or -□3 master hardware under the documented optical-link configuration. In a dual-redundant arrangement, use matching module types on ESB bus 1 and bus 2.
ManufacturerYokogawa
ModelANT502-50/BU1A S1
Product typeOptical ESB Bus Repeater Slave Module
System familyCENTUM VP N-IO/FIO
FunctionESB bus optical transport
Maximum optical hop5 km
Current consumption0.5 A
Main-body weightApproximately 0.25 kg
Optical connectorLC; IEC 61754-20
Optical fiberQuartz single-mode fiber
Required fiber cores2
Permissible optical loss0 to 10 dB at 1.3 μm
Maximum chain hops2
TopologyChain and star connections
Bus connector option/BU1A: connector unit with ESB bus connector
Protection code-5: standard type with no explosion protection
Configuration code0: basic type, for maintenance purpose
Installable unitANB11 series or ANT10U
Redundant installationPaired consecutive slots; ESB bus 1 in odd slot, bus 2 in even slot
Single configurationFit a dummy cover to the paired even-numbered slot
FAQ

ANT502-50/BU1A S1 Optical ESB Bus Repeater Slave Module FAQ

What does ANT502-50/BU1A S1 do on the optical ESB link?+

ANT502-50/BU1A S1 operates on the slave side of an optical ESB connection. It receives the optical link and interfaces with the node-side ESB bus. The documented maximum is 5 km per optical hop.

Which optical fiber and connector are specified for ANT502-50/BU1A S1?+

ANT502-50/BU1A S1 uses an LC optical connector and two-core quartz single-mode fiber. Yokogawa specifies an optical loss allowance of 0 to 10 dB at 1.3 μm; the selected cable must also meet the 5 km hop limit.

What does /BU1A specify for ANT502-50/BU1A S1?+

ANT502-50/BU1A S1 includes the supplied /BU1A reference for a connector unit with an ESB bus connector. /BU1B is a separate connector-unit option, while /HU1A and /HU1B identify HKU-interface arrangements.

Which master variants match ANT502-50/BU1A S1?+

ANT502-50/BU1A S1 belongs to the 0/3 optical pairing group. Pair the -50 variant with ANT401-□0 or -□3 master hardware under the documented optical-link configuration. Do not select a different pairing group simply because its connector or family name looks similar.

Where can ANT502-50/BU1A S1 be installed?+

ANT502-50/BU1A S1 installs in the documented ANB11 node-unit or ANT10U repeater-unit positions. Slot allocation differs for single and dual-redundant arrangements; use the unit-specific allocation table before fitting the module.

How is ANT502-50/BU1A S1 arranged for dual redundancy?+

ANT502-50/BU1A S1 uses consecutive paired slots in the documented redundant arrangement. Install ESB bus 1 in the odd-numbered slot and bus 2 in the even-numbered slot, and use the same module type on both buses.

What current consumption and weight are listed for ANT502-50/BU1A S1?+

ANT502-50/BU1A S1 is covered by Yokogawa specifications listing 0.5 A current consumption and approximately 0.25 kg for the main body. The main-body figure does not describe a complete node assembly or shipment packaging.

CONTACT PRODUCT SPECIALIST

Check ANT502-50/BU1A S1 application details with Frida

Provide the ANT502-50/BU1A S1 nameplate, installed unit, master/slave pairing, connector option, optical distance, required quantity and destination.

CHOOSE A DIRECT CONTACT METHOD
DATA SHEET

Official Hardware Specifications for
ANT502-50/BU1A S1

Yokogawa GS 33J60F51-01EN covers ANT401 and ANT502, including the -50 and -5E configurations and the listed connector options. Refer to the matching optical-pairing notes when selecting hardware.

ANT502-50/BU1A S1 official hardware reference

The official series PDF includes standard specifications, optical-fiber requirements, installation slots and model/suffix tables. It covers the base and ordering options shown here; the supplied S1 marking is retained without assigning undocumented electrical or compatibility differences.

VIEW OFFICIAL SERIES PDF

Contact to Get Support

Provide the ANT502-50/BU1A S1 nameplate, installed unit, master/slave pairing, connector option, optical distance, required quantity and destination.

Reference: Yokogawa GS 33J60F51-01EN, standard specifications, installation and model/suffix tables. Match the master/slave configuration group and connector option; this is not an individual-unit certificate.

YOKOGAWA MODULE · MODEL IDENTIFICATION

How ANT502-50/BU1A S1 Is Identified

Yokogawa GS 33J60F51-01EN defines the following literal model and option segments. S1 is retained as supplied, without assigning undocumented characteristic changes.

Yokogawa · BRAND
ANT502-50/BU1A S1 Optical ESB Bus Repeater Slave ModuleOFFICIAL MODEL REFERENCE
MODULE FAMILY

ANT502

Optical ESB Bus Repeater Slave Module

PROTECTION TYPE

-5

Standard type with no explosion protection

CONFIGURATION

0

Basic type; maintenance purpose

CONNECTOR OPTION

/BU1A

Connector unit with ESB bus connector

Model reference: Use the optical pairing group and bus connector option together. S1 remains in the complete supplied reference.
APPLICATION AREAS

Applications for ANT502-50/BU1A S1

Distributed ESB Transport

Extends the electrical ESB bus through an optical link of up to 5 km per hop.

Node-Side Optical Link

Links the matching optical hardware to the documented node-side ESB bus.

PRODUCT REFERENCEANT502-50/BU1A S1Yokogawa optical esb bus repeater slave module
Chain Connection

Supports the documented chain topology, with a maximum of two optical hops.

Star Connection

Supports the documented star topology with the applicable field control and repeater hardware.

ABOUT MOORE AUTOMATION

A trusted industrial automation sourcing partner

Moore Automation Limited supplies industrial automation spare parts to customers worldwide, with dedicated sourcing, part-number verification, pre-shipment confirmation and responsive sales support.

Global sourcing Pre-shipment verification One-year warranty
SERVICE

Industrial Automation Order Support

A clear workflow for sourcing, verification, shipment preparation, delivery and product assurance.

STAGESERVICE ACTIONWHAT WE CHECK OR PROVIDE
01PROCUREMENT
Product SourcingCurrent, hard-to-find and discontinued industrial automation parts.
02VERIFICATION
Part Number ReviewComplete model, suffix, nameplate, visible revision and application details.
03CONFIRMATION
Pre-Shipment CheckModel, label, condition and packaging confirmed with actual photos or video.
04FULFILLMENT
Global Delivery
Worldwide delivery with flexible shipping options. We support door-to-door pickup or delivery to your nominated freight forwarder in China.
DHLFedExUPSTNT
05ASSURANCE
One-Year WarrantyOne-year warranty from delivery for products supplied by Moore Automation.
Warranty Claim Information+
What to provide: If a product-related issue occurs within the warranty period, contact our team and submit one clear, continuous video for review.
✓Complete product and nameplate
✓Power supply and wiring connections
✓Installation and operating conditions
✓Indicator lights, alarms or error messages
✓Clear description of the fault
✓Continuous video showing the issue
Review outcome: If the evidence confirms a covered product fault, Moore Automation will arrange the appropriate warranty solution.
SALES ASSISTANCE

Contact Sales Manager Frida

Include the complete part number, quantity and delivery destination.

EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
hinterlass eine Nachricht
Wenn Sie an unseren Produkten interessiert sind und mehr Details erfahren möchten, hinterlassen Sie bitte hier eine Nachricht, wir werden Ihnen so schnell wie möglich antworten.
  • SPS
  • DCS
  • TSI
  • HMIS
Verwandte Produkte